WitrynaIf the switch or fuse is placed in the neutral wire, the electrical appliance is still connected to the high voltage live wire even when the switch is open, or the fuse is blown. WitrynaLive wire: Copper wire coated with brown plastic along which the current enters the device. Fuse : A glass or ceramic canister containing a thin wire that melts if the current gets too high ...

Mains cables - Mains electricity - AQA Synergy - BBC Bitesize

WitrynaThe live wire and neutral wire, coming from the electric pole, enter a box fitted just outside our house which has a main fuse F1. The fuse is connected in series with the live wire. This is done so because it is only the live wire which has a high potential of 220 volts unlike the neutral wire which carries zero potential. Witryna21 paź 2024 · A live wire (phase) is a cable used to supply electricity to a device. neutral acts as a way back to complete the circuit.if the fuse is given to the neutral wire, after the fuse breaks out, there is still electricity coming from the wire (phase) of life through the appliance until the fuse. heart cliff in algarve portugal https://boudrotrodgers.com

Household electricity - Mains electricity - Edexcel - BBC …

WitrynaThere is no ground connection unless there is a fault and one of the wires touches something earthed. Then the other-wire becomes live. In (b) the battery negative has been connected to earth. It is grounded or neutralised and the other wire is 9 V with respect to earth. Witryna28 cze 2024 · The fuses are placed in the positive lines from the battery and close to the battery. If a fault occurs on the line between the fuse and the load the fuse blows and current flow stops. A ground fault on the return line is unlikely to cause any problems as there is no significant voltage on it. Witryna24 wrz 2015 · Does that not mean that both the live and neutral wires carry the same amount of current, alternatively? Yes,they do. As I have mentioned above. The live wire carries the current towards domestic appliances and others instruments and the neutral wire emerges from the appliance and carries the current back to source. heart clinic arkansas

Earthing - Electricity in the home - CCEA - BBC Bitesize

Category:What is the difference between live wire and earth wire?

Tags:Is the fuse connected to the live wire

Is the fuse connected to the live wire

Domestic Electric Circuit - Diagram, Wires, Fuse

WitrynaFuses A fuse provides a built-in fail-safe to the electrical circuit for a device. The fuse contains a thin wire that will melt if the current gets too high. If there is a fault that causes... WitrynaThe reason is that in the case of over-loading, if fuse wire is connected in neutral wire, it will certainly melt and break, but the electric appliance still be in contact with the live wire, so if any person happens to touch the appliance, he will get a shock which may prove fatal. Concept: Electric Fuse

Is the fuse connected to the live wire

Did you know?

WitrynaThe wire covered in brown plastic is the live wire. This carries the 230 V alternating potential difference from the power supply. The wire covered in blue plastic is the neutral wire and... WitrynaThe live wire, having a voltage of around 230 V, is the most dangerous one As a result of this, fuses and switches are always connected to the live wire This means that when a switch is turned off (or a fuse blows) a device will no longer be connected to the live supply The circuit symbol for a fuse

WitrynaThe earth wire protects us from an electric shock. A switch should not be touched with wet hands. AH electrical appliances in a household circuit work at the same voltage. In a cable, green wire is the live wire. A fuse is connected to the live wire. A switch is connected to the neutral wire. Answer: Solution: False False False False True True WitrynaFuse connected in the circuit's live wire: It is understood that the overloading in the circuit can damage the connected device. Whenever there is overloading in the circuit, the fuse wire melts because it is made up of high resistance material.

WitrynaThe fuse is connected to one of the wires inside the cable. (i) Which one of the wires inside the cable is the fuse connected to? [1 mark] (ii) The fuse is a thin wire inside a closed glass tube. The wire acts as a resistor. What effect does a current through a wire have on the wire? [1 mark] Witryna26 paź 2014 · There must be two wires for a complete circuit.. Now, in a balanced AC circuit, both wires provide an alternating voltage with respect to ground (earth). When one wire is positive, the other is negative. However, in an unbalanced system, one wire is neutral, which should ideally be at 0V with respect to ground, and the other is hot …

WitrynaA plug connects a device to the mains electricity supply. The cable between the device and the three-pin plug contains three copper wires that are coated with plastic. copper wires are good...

Witryna(b) The diagram shows how the electric supply cable is connected to an electric kettle. The earth wire is connected to the metal case of the kettle. If a fault makes the metal case live, the earth wire and the fuse inside the plug protect anyone using the kettle from an electric shock. Explain how. heart clinic arkansas kanisWitrynaBoth fuse and switch are safety features which must be connected in the live wire. If connected wrongly e.g. on neutral wire, they do not serve their purpose.... heart click soundWitrynaFuse is always connected to a live wire. If fuse wire is connected to neutral wire instead of live wire then even when the fuse burns out the appliance remains connected to the live wire and the current supplied will not be disrupted due to overloading. Was this answer helpful? 0 0 Similar questions How is the fuse wire … heart clinic decatur alhttp://misssugarscience.weebly.com/uploads/9/7/0/3/97036086/10_-_electricity_in_the_home_old_exam_questions.pdf heart clinic in harlingen texasWitrynaA fuse wire is connected in series with live wire. If we connect the fuse in the neutral wire in the circuit, then due to excessive flow of electric current when the fuse burns, current will stop flowing in the circuit, but the appliance will still remain connected to the higher potential through the live wire. So the user might get an electric shock even … mount baker rhythm \u0026 blues festival 2023Witryna25 lis 2024 · The live wire is connected directly to the generators of the current supply company. The main fuse is connected to the live wire. If a fault occurs where the live wire is connected then the Earth wire allows a large current to flow through the live and Earth wires. Wires Electricity Physics FuseSchool Watch on heart clinic arkansas heber springsWitrynaThe fuse is always connected to the live wire AND its also connected as close to the entry to the device as possible. This assures that when the fuse is activated (blown) that as much live wire circuitry is disconnected as possible. That ensures that the disconnected circuitry is basically all at the potential of the neutral wire which in most ... heart clinic in harlingen